Fireworks Electrical Igniter Cable
Listed below are suggested high resistance wires for use in making electrical firing systems. General recommendations are that the wires used for ignition need a to have a resistance range of 650 to 875 ohms/cmf, with the higher end of the range being the best suited. Melt point of the wire needs to be in the range of 1100-1500° C.
| Composition | Resistance |
Melt Point (°C) |
Also Known As | |
| EvanOhm | 75%
Nickel |
800 | 1400° C |
|
| NiCr 80 | 80% Nickel |
650 | 1200° C |
|
NiCr 60 |
60% Nickel |
675 | 1390° C |
|
| Alloy 815 | 22% Chrome 73.2% Iron 4.8% Aluminium |
815 | 1500° C |
|
| Alloy 837 | 22% Chrome 72.7% Iron 5.3% Aluminium |
836 | 1500° C |
|
| Alloy 875 | 22% Chrome 72.2% Iron 5.8% Aluminium |
875 | 1500° C |
|